Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Journal of Central South University(Medical Sciences) ; (12): 998-1000, 2016.
Article in English | WPRIM | ID: wpr-815145

ABSTRACT

Aortoesophageal fistula (AEF) is a rare but fatal complication caused by foreign body ingestion. Aortic replacement and endovascular stent graft are the common repair surgeries. The materials to repair an aortic defect in AEF are typically homograft or allograft, but the use of an autologous pericardium patch is rarely reported. Here we reported a patient with AEF and severe mediastinal infection induced by chicken bone ingestion. In this case, the autologous pericardium patch was used as the repair material.


Subject(s)
Humans , Aorta , Wounds and Injuries , General Surgery , Aortic Diseases , General Surgery , Autografts , Transplantation , Esophageal Fistula , General Surgery , Foreign Bodies , Gastrointestinal Hemorrhage , General Surgery , Mediastinal Diseases , General Surgery , Pericardium , Transplantation , Stents , Transplantation, Autologous , Methods , Vascular Fistula , General Surgery , Vascular Grafting , Methods
2.
Journal of Biomedical Engineering ; (6): 426-431, 2014.
Article in Chinese | WPRIM | ID: wpr-290741

ABSTRACT

We developed and designed a new type of artificial trachea. The basic structure of the artificial trachea was polytetrafluoroethylene vascular prosthesis linked with titanium rings on both sides. Dualmesh was sutured on titanium rings. This experimentation follows the replacement of trachea in dogs with a combined artificial trachea to investigate the feasibility of this type of prosthesis. Sixteen dogs were implanted with the combined artificial trachea after resection of 5 cm of cervical trachea. The 5 cm-long trachea of dogs on the necks were resected and the reconstruction of the defect of the trachea was performed with trachea prosthesis. According to the method of trachea reconstruction, the models were divided into 2 groups, artificial trachea implantation group (the control group, n = 8) and group of artificial trachea implantation with growth factor (the experimental group, n = 8). Then computer tomography scan (CT), bronchoscope and pathologic examination were conducted periodically to observe the healing state of the hybrid artificial trachea. None of the dogs died during operation of cervical segmental trachea construction. But four dogs in the control group died of apnea in succession because artificial trachea was displaced and the lumen was obstructed, while 2 dogs died in the experimental group. In the first month there was granulation around anastomosis with slight stenosis. The rest of dogs were well alive until they were sacrificed 14 months later. The mean survival time of the experimental group was longer than that of the control group. The rate of infection, anastomotic dehiscence, severe stenosis and accidental death in the experimental group were lower than the control group (P < 0.05). Artificial trachea was encapsulated by fibrous tissue and no mucous membrane was seen in the lumen of the artificial trachea. The artificial trachea can be used to reconstruction of the defect of the trachea with long-term survival of the animals. The unique design of artificial trachea reduces stenosis around anastomosis effectively but infections and split or displacement of the artificial trachea are still major problems affecting long-term survival of the animals. Application of growth factors to a certain extent promotes tissue healing by changing the local environment.


Subject(s)
Animals , Dogs , Artificial Organs , Prostheses and Implants , Prosthesis Design , Prosthesis Implantation , Plastic Surgery Procedures , Titanium , Trachea , General Surgery
SELECTION OF CITATIONS
SEARCH DETAIL